HOME  ITALIAN       |       
Untitled Document
   
 
CATALOGUE > AUTO
Download data sheet
 
SINGLE-CORE CABLES FOR AUTOMOTIVE INDUSTRY.


 
1/2 table
 
 STANDARDS   PACKAGING  
 
 
  CHARACTERISTICS
 
Rated voltage: < 50 V a.c.
< 75 V d.c.
   
 
Type Class

Operating
temp.
3000h

Operating
temp.
48h

Insulation Applications Norms
             
T1 A -25 ÷ +85° C 105° C PVC
rear area of the cabin
ISO 6722
T2 B -40 ÷ +105° C 125° C PVC
in hot environments with no direct heat contact on the cable
ISO 6722
T3 C -40 ÷ +125° C 155° C PVC or PP compound
in hot environments with no direct heat contact on the cable
ISO 6722
T3 SP D -40 ÷ +125° C 155° C cross-linked polyolefines
T3 when high mechanical performances are required
ISO 6722
T4 - -40 ÷ +150° C 180 °C TPE-E
high exposure to heat sources on the cable
ISO 6722
   
 
Section Max. diam.
of conductor
Insulation
thickness
Diameter

Max. resistance
at 20°C

Cable
weight
mm² mm mm mm ohms/km kg/km
  Standard insulation thickness
0,35 0,21 0,4 1,5 57,9 5
0,5 0,21 0,6 2,1 39 9
0,8 0,31 0,65 2,5 24,4 12
1 0,31 0,6 2,5
19 15
1,5 0,31 0,8 3,3 12,9 24
2,5 0,31 0,85 3,7 7,83 33
4 0,31 0,95 4,5 4,86 53
6 0,31 0,95 5,1 3,27 70
10 0,41 1,05 6,9 1,83 135
16 0,41 1,85 8,8 1,15 216
25 0,36 1,4 10,1 0,78 309
35 0,41 1,4 12,0 0,551 426
50 0,41 1,6 13,8 0,385 621
  Thin insulation thickness
0,5 0,21 0,3 1,8 37,1 8
0,8 0,21 0,3 2,2 23,5 11
1 0,21 0,3 2,2 18,5 13
1,5 0,26 0,3 2,7 12,7 19
2,5 0,26 0,35 3,2 7,6 30
4 0,31 0,35 4,1 4,71 48
6 0,31 0,4 4,7 3,14 69
  Very thin insulation thickness
0,35 0,26 0,2 1,3 52 5
0,5 0,21 0,22 1,5 37,1 6
0,75 0,21 0,24 1,8 24,7 9
1 0,21 0,24 1,9 18,5 12
1,5 0,26 0,24 2,3 12,7 17
2 0,3 0,3 2,6 9,42 21
2,5 0,26 0,28 2,8 7,6 28
4 0,31 0,32 3,5 4,7 42
6 0,31 0,32 4,1 3,1 61
8 0,32 0,9 5,6 2,26 95
10 0,4 1,05 6,9 1,76 135